电压击穿试验仪技术要求:
III. Technical Requirement:
01、电压击穿试验仪输入电压: 交流 220 V
01. Input Voltage: AC 220 V
02、输出电压: 交流 0--50 KV ;
02. Output Voltage: AC 0--50 KV;
直流 0—50 KV
DC 0—50 KV
03、电压击穿试验仪电器容量: 3KVA
03. Capacitance of Electrical Device: 3KVA
04、电压击穿试验仪高压分级: 0--5KV; 0-10KV; 0--20KV;0--50KV
04. High Voltage Hierarchy: 0--5KV; 0-10KV; 0--20KV; 0--50KV
05、升压速率: 100 V/S 200 V/S 500 V/S 1000 V/S 2500 V/S 5000 V/S
(备注:电压击穿试验仪可以根据用户需求设定不同的升压速率)
05. Rate of Voltage Boost: 100 V/S 200 V/S 500 V/S 1000 V/S 2500 V/S 5000 V/S
(Note: Different rates of voltage pressure available according to user’s different requirement)
06、试验方式:
06. Test Method:
电压击穿试验仪直流试验:1、匀速升压 2、梯度升压 3、耐压试验
电压击穿试验仪交流试验:1、匀速升压 2、梯度升压 3、耐压试验
DC Test: 1. Voltage boost at constant velocity 2. Gradient voltage boost 3. Withstand voltage test
AC Test: 1. Voltage boost at constant velocity 2. Gradient voltage boost 3. Withstand voltage test
07、电压击穿试验仪安装灵敏度较高的过电流保护装置保证试样击穿时在0.1S内切断电源
07. The tester is equipped with the high-sensitivity over-current protective device to ensure that the power is cut off within 0.1S when breaking down the sample.
08、电压击穿试验仪采用先进的无触点原件匀速调压方式。
08. The tester adopts the advanced non-contact original voltage regulation mode at constant velocity.
09、支持短时间内短路试验要求。
09. The tester supports short circuit test in a short period.
10、电压击穿试验仪电压试验精度: ≤ 1%
10. Precision of voltage test: ≤ 1%
11、电压击穿试验仪试验电压连续可调: 0--50 KV
11. Test voltage to be continuously regulatory: 0--50 KV
12、电压击穿试验仪耐压时间设定:0-6小时
12. Withstand voltage duration setting: 0-6h
13、支持20S,60S急速升压.
13. The tester supports 20S and 60S voltage boost at high velocity.