斐卓水泥SNCR(氨水)脱硝工程详细说明:
斐卓公司的SNCR(氨水)脱硝系统主要包含:卸氨系统、储存系统、清水系统、混合系统、加压系统、计量系统、分配系统、雾化系统、冲洗系统、喷淋系统、排污系统、控制系统。
系统的特点如下:
不使用催化剂,不产生固体废料;
自动化程度高,不需要还原剂的溶解过程;
故障报修率低,操作简单便捷;
脱硝效率高,投资低。
对水泥生产工艺和水泥质量没有任何影响;
The Fijian zhuo cement SNCR (ammonia) denitration project details:
To the Fiji SNCR (ammonia) denitration system mainly includes: ammonia unloading system, storage system, water system, mixing system, pressure system, measuring system, distribution system, atomization system, rinse system and spray system, sewage system, control system.
The characteristics of the system are as follows:
Do not use the catalyst, do not produce solid waste;
A high degree of automation, don't need reductive dissolution process;
The fault the repair rate is low, operation simple and convenient;
High denitration efficiency, low investment.
No difference to the quality of cement production process and cement;
FM脱硝喷枪-气体、液体在空气帽腔体内部混合
雾化,雾化原理为空气破裂和撞击,具有雾化颗粒直径小,覆盖面广,穿透力强等优点。
FM雾化脱硝喷枪连接体-标准结构
喷雾枪头
实心锥型
①喷雾角度:
0-90°
②流量参数:
0-15L/Min
③喷嘴材质:
316L/310SS
扇形
①喷雾角度:
0-120°
②流量参数:
0-5L/Min
③喷嘴材质:
316L/310SS
连接枪杆(标准)
1、法兰连接
2、快拆连接(带冷却风)
L1:有效工作长度
L2:枪杆可调长度
D:喷枪外径
枪体材质:310SS/316L
设计特点:
1、面对不同的工况可选择两种不同的喷雾形式(多孔实心锥型、扇形),同时在两种不同类型下又可选择在范围内的任意合适角度,以此来满足复杂的脱硝环境。
2、根据现场的实际环境选择不同的喷枪固定方式,同时喷枪使用长度可调节,
大大增加了喷枪的使用灵活性。
3、喷枪气体、液体管路与气液母管道采用软管连接,具有拆卸使用方便,容易维护等优点。
4、冷却风能有效的增加喷枪在SNCR烟气中的使用寿命,同时可在喷嘴处增加碳化硅保护套管,使用寿命更长,但压缩空气使用量增加。
型号:
型号:
型号:
型号:
更多详情请咨询www.feizhuo.net
雾化喷枪的常用维修方法:
雾化 喷枪在使用的过程当中有时会出现一些问题,现就喷枪出现的现象进行详细的分析,并根据出现的现象剖析原因,找出解决办法。
一、现象:喷幅形状呈重心偏向一侧
原因:气帽中心孔或雾化孔堵塞
对策:1、清洁雾化帽
2、更换雾化帽
二、现象:偏左或偏右
原因:1、气帽一侧的扇面控制孔堵塞
2、气帽受损
对策:1、清洁雾化帽
2、更换雾化帽
三、现象:喷幅中央过厚
原因:1、喷涂的涂料黏度太高
2、喷涂压力太低
3、喷嘴的口径和顶针由于磨损而增大和变小
对策:1、调低涂料黏度
2、增大喷涂压力
3、更换喷嘴套装
四、现象:喷幅分裂
原因:1、涂料黏度太低
2、喷涂压力太高
3、扇面控制孔内径偏大
4、涂料不够
5、雾化空气通道堵塞
对策:1、调高涂料黏度
2、调低喷涂压力
3、更换喷嘴套装
4、添加足够的涂料
5、清洁喷枪的空气通道
五、现象:跳枪
原因:1、喷嘴没拧紧或没装好
2、枪针密封套件松动
3、喷枪的连接螺母松动(下壶喷枪)
4、壶里涂料不足
5、喷嘴套装损坏
对策:1、旋紧喷嘴或清洁并安装喷嘴套装
2、紧固顶针密封套件
3、旋紧连接螺母
4、补充涂料
5、更换喷嘴套装
六、现象:喷幅上重或下重
原因:1、喷嘴、顶针或气帽的空气出口上有杂物堵塞
2、